Product: Igniters
Proper Shipping Name: IGNITERS
Description of Effect Produced
(Distances shown are approximate and for guidance only, they are not safety distances)
Purpose: Used as an initiator for pyrotechnic products
Duration: Instant
Resistance: 0.9± 0.15 ohm
Max Non-Fire Current: 0.30 A
Min. Firing Current: 0.55 A
All Fire Current: 1.35A
Test Current: 10.0 mA
Additional Notes: Igniter produces a small amount of sparks and slight noise
Warning
Inhalation of smoke produced from the effect should be avoided. Excessive smoke inhalation may cause
respiratory irritation, difficulty in breathing, headaches, nausea and may result in vomiting. In normal use
with adequate ventilation the smoke produced should not be a problem. However any person found to be
suffering from smoke inhalation should be removed to fresh air and medical assistance sought.
In the Event of a Mis-Fire
If the device fails to fire, isolate the effect from the firing system. Check that the circuit has been
connected correctly and repeat the firing sequence. If unsuccessful disconnect the firing circuit again,
remove the device from its firing position and return to its original packaging to await disposal.
Storage Conditions
Store in a cool dry place, humidity should preferably be less than 70%. Avoid extreme temperatures. In
particular sub-zero temperatures where freezing and re-thaw can alter the performance of the article.